Wuxi Fenigal Bilim ve Teknoloji Co, Ltd

Üretici ve Tedarikçi Elektrik ve Aydınlatma Ürünleri

Ana sayfa
Ürünler
Hakkımızda
Fabrika turu
Kalite kontrol
Bize ulaşın
Teklif isteği
Ana sayfa ÜrünlerEndüstriyel Elektrik Kontrolleri

CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1

CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1

    • CJX2-N AC Reversing Contactor , 3 Phase Reversing Contactor 3P 4P 9A~95A AC-3 AC-1
    • CJX2-N AC Reversing Contactor , 3 Phase Reversing Contactor 3P 4P 9A~95A AC-3 AC-1
    • CJX2-N AC Reversing Contactor , 3 Phase Reversing Contactor 3P 4P 9A~95A AC-3 AC-1
    • CJX2-N AC Reversing Contactor , 3 Phase Reversing Contactor 3P 4P 9A~95A AC-3 AC-1
  • CJX2-N AC Reversing Contactor , 3 Phase Reversing Contactor 3P 4P 9A~95A AC-3 AC-1

    Ürün ayrıntıları:

    Menşe yeri: Çin
    Marka adı: Chint
    Sertifika: CE,CCC,CB etc.
    Model numarası: CJX2-N-

    Ödeme & teslimat koşulları:

    Min sipariş miktarı: 1 ADET
    Fiyat: USD15~USD138
    Ambalaj bilgileri: Standart ihracat karton
    Teslim süresi: 5-8 iş günü veya toplu sipariş müzakere
    Ödeme koşulları: T/t, Western Union
    Yetenek temini: 1,000pcs / ay
    Şimdi başvurun
    Detaylı ürün tanımı
    Ana devre akımı: 9-95A Elektrik tipi: AC, AC / DC
    Ana devre voltajı: 600V, 220V, 380V, 110V, 24V Kutup sayısı: 3,4
    Aşama: 3,1Phase Frekans: 50 / 60Hz
    Ürün adı: Ac Kontaktörü CJX2N-D09,3 kutuplu Ac Kontaktörü Anma: 95A
    Standart: IEC60947'ye, EN / IEC60947-4-1

    Chint CJX2-N AC Ters Çevirme Kontaktörü 3P, 4P 9A ~ 95A 1810, 2510, 3210, 6511, AC-3 AC-1 Bobin Gerilimi 24V, 110V, 230V, 380V

    karakteristik
    • Akım aralığı 09 ~ 95A;
    • AC, DC kontrol bobini isteğe bağlıdır (38C'ye DC bobini);
    • Farklı tipte starterler mevcuttur: standart motor start kontaktörleri, geri dönüşümlü kontaktörler, yıldız üçgen starterler, ototransformer starterler, vb.
    • İsteğe bağlı bağlantı: cıvata bağlantısı (09 ​​~ 620A), halka terminal bağlantısı (09 ​​~ 38A), terminal bağlantısı (40 ~ 65A), müşteri montajı için uygun;
    • Ürün Belgelendirme: CCC, CE, CCS;


    avantaj
    • Kompakt kurulum
    > 38A kontaktörleri ve koruma bileşenleri sadece 45mm genişliğindedir
    > Aşırı gerilim önleyici kurulum alet gerektirmez ve daha fazla yer kaplamaksızın doğrudan kontaktöre yerleştirilebilir
    > Ters çevrilebilir kontaktör sadece 90mm genişliğindedir, mekanik kilitleme fazladan yer kaplamaz, kurulum neredeyse zaman almaz
    > Starter bileşenleri hızlı ve kolay montaj için önceden kablolanmış modüller sağlar
    • Son derece entegre
    > 100A kontaktör entegrasyonu için 1 normalde açık / 1 normalde kapalı yardımcı kontak
    > Dahili çift yönlü baskılama diyotlu DC bobin
    > Dahili çift yönlü bastırma diyotlu ters çevrilebilir kontaktör grubu
    • Güvenli ve güvenilir
    > Kontrol ve koruma bileşenlerinin ana devresi ve kontrol devresi açıkça ayırt edilir
    > Güvenlik standartlarını karşılayan ve 10 milyon güvenilir eylemi sağlayan aynalı temas tasarımı
    > Koruyucu kapak, kontaktörün kazayla temasını önler
    • üstün kalite
    > DC bobinleri çok çeşitli kontrol voltajlarına sahiptir (0,7 ~ 1,25Uc)
    > Güçlü depreme dayanıklı
    > düşük ses
    > Artan terminal gücü
    CJX2 40-65A:
    > Kalıcı tork, güvenilir kurulum
    > Kompakt ve yerden tasarruf
    > Kurulumu kolay, zaman kazandırır
    > Kolay bakım ve maliyet tasarrufu

    main information
    Product Series
    NC
    product name
    devre açıcı
    product type
    Reversing contactor
    Product short name
    CJX2-N
    Contactor application area
    Applied to AC loads with a power factor greater than or equal to 0.95
    Squirrel cage motor for switching on and off normal start
    Use category
    AC-1
    AC-3
    Equipment introduction
    Pre-assembled with reversible power supply busbar
    Number of poles
    3P
    Power pole contact composition
    3 NO
    Rated working voltage [Ue]
    Power circuit: <= 690 V AC 25...400 Hz
    Power circuit: <= 300 V DC
    Rated operating current [Ie]
    25 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit
    40 A 60 °C) on <= 440 V AC AC-1 for power supply circuits
    Motor power (kW)
    5.5 kW on 220...230 V AC 50/60 Hz
    11 kW on 380...400 V AC 50/60 Hz
    11 kW on 415...440 V AC 50/60 Hz
    15 kW on 500 V AC 50/60 Hz
    15 kW on 660...690 V AC 50/60 Hz
    Motor power HP (UL / CSA)
    3 hp on 230/240 V AC 50/60 Hz for 1-phase motors
    5 hp on 200/208 V AC 50/60 Hz for 3-phase motors
    2 hp on 115 V AC 50/60 Hz for 1-phase motors
    7.5 hp on 230/240 V AC 50/60 Hz for 3-phase motors
    15 hp on 460/480 V AC 50/60 Hz for 3-phase motors
    20 hp on 575/600 V AC 50/60 Hz for 3-phase motors
    Control loop characteristics
    AC on 50/60 Hz
    Control loop voltage
    220 V AC 50/60 Hz
    Auxiliary contact type
    1 NO + 1 NC
    Rated impulse withstand voltage [Uimp]
    6 kV in accordance with IEC 60947
    Overvoltage category
    III
    Conventional heating current [Ith]
    10 A on <60 °C for signal circuit
    40 A on <60 °C for power supply circuit
    Rated turn-on capability [Irms]
    140 A AC suitable signal circuit in accordance with IEC 60947-5-1
    250 A DC suitable signal loop in accordance with IEC 60947-5-1
    450 A on 440 V applicable power supply circuit in accordance with IEC 60947
    Rated breaking capacity
    450 A on 440 V applicable power supply circuit in accordance with IEC 60947
    Rated short-time withstand current [Icw]
    50 A on <40 °C - 10 minutes for power circuit
    120 A on <40 °C - 1 minute for power circuit
    240 A on <40 °C - 10 s for power supply circuit
    380 A on <40 °C - 1 s for power supply circuit
    100 A - 1 s for signal circuits
    120 A - 500 ms Applicable signal loop
    140 A - 100 ms for signal circuits
    Fuses used with relays
    10 A gG Applicable signal circuit in accordance with IEC 60947-5-1
    63 A gG on ...<= 690 V with type 1 for power supply circuit
    40 A gG on ...<= 690 V with type 2 for power supply circuit
    Average impedance
    2 mΩ - Ith 40 A 50 Hz for power supply circuits
    Rated insulation voltage [Ui]
    690 V complies with IEC 60947-4-1
    600 V CSA certification
    600 V UL certification
    690 V in accordance with IEC 60947-1
    Electrical life
    1.65 kA2.s 25 A AC-3 Ue condition <= 440 V
    1.4 kA2.s 40 A AC-1 Ue condition <= 440 V
    Power consumption per pole
    1.25 W AC-3
    3.2 W AC-1
    Safety cover
    band
    Interlock type
    mechanical
    Installation method
    Rail mounting
    Base plate installation
    Standards compliant
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    EN 60947-4-1
    certified product
    CCC
    Wiring ability
    Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord without
    Control circuit: Bolt fastening 2 Cable 1...4 mm2 cord without
    Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord
    Control circuit: Bolt fastening 2 Cable 1...2.5 mm2 cord
    Control circuit: Bolt fastening 1 Cable 1...4 mm2 hard wire without
    Control circuit: Bolt fastening 2 Cable 1...4 mm2 hard wire without
    Power circuit: Bolt fastening 1 Cable 2.5...10 mm2 cord without
    Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 cord without
    Power circuit: Bolt tightening 1 Cable 1...10 mm2 cord
    Power circuit: bolt fastening 2 cable 1.5...6 mm2 cord
    Power circuit: bolt fastening 1 cable 1.5...10 mm2 hard wire without
    Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 hard wire without
    Tightening torque
    Control circuit: 1.7 Nm Screwdriver with bolt Ø 6 flat
    Control circuit: 1.7 Nm Screwdriver with No 2 Phillips screw
    Power circuit: 2.5 Nm Screwdriver with bolt Ø 6 flat
    Power circuit: 2.5 Nm Screwdriver with No 2 Phillips screw
    Action time
    12...22 ms closed
    4...19 ms break
    Safety and reliability
    B10d = 1369863 Contactors with nominal load compliance in accordance with EN/ISO 13849-1
    B10d = 20000000 mechanical load contactors comply with EN/ISO 13849-1
    Mechanical life
    15 kA2.s
    Maximum operating frequency
    3600 times / hour on ... <60 °C
    Additional information
    Surge suppression module
    No built-in surge suppression module
    Control voltage limit
    Release: 0.3...0.6 Uc on 50/60 Hz 60 °C)
    Operation: 0.8...1.1 Uc on 50 Hz 60 °C)
    Operation: 0.85...1.1 Uc on ... 60 Hz 60 °C)
    (~50Hz pull-in) power consumption (VA)
    70 VA 60 Hz 0.75 20 °C)
    70 VA 50 Hz 0.75 20 °C)
    (~50Hz hold) power consumption (VA)
    7.5 VA 60 Hz 0.3 20 °C)
    7 VA 50 Hz 0.3 20 °C)
    Heat dissipation
    2...3 W on 50/60 Hz
    Auxiliary contact type
    Type mechanical connection 1 NO + 1 NC in accordance with IEC 60947-5-1
    Type mirrored to the main contact state 1 NC in accordance with IEC 60947-4-1
    Signal loop frequency
    25...400 Hz
    Minimum switching current [Imin]
    5 mA suitable signal loop
    Minimum switching voltage
    17 V for signal circuit
    No overlap time
    1.5 ms between power loss NC and NO contact
    1.5 ms between the NC and NO contacts
    Insulation resistance
    > 10 MΩ for signal circuits
    surroundings
    IP protection level
    IP20 front panel complies with IEC 60529
    Protective measures
    TH conforms to IEC 60068-2-30
    Pollution level
    3
    Operating temperature
    -5...60 °C
    Storage ambient temperature
    -60...80 °C
    Ambient air temperature
    -40...70 °C (allowed under Uc)
    Working elevation
    3000 m without
    Refractory and resistant to abnormal high temperatures
    850 °C in accordance with IEC 60695-2-1
    Flame retardant
    V1 complies with UL 94
    Shock and vibration resistance
    Seismic performance contacts open: 2 gn (5...300 Hz)
    Seismic performance contact closure: 4 gn (5...300 Hz)
    Impact resistance contact closure: 15 gn (11ms)
    Impact resistance contacts open: 8 gn (11ms)
    height
    85 mm
    width
    90 mm
    depth
    92 mm
    product weight
    0.787 kg


    İletişim bilgileri
    Wuxi Fenigal Science & Technology Co., Ltd.

    İlgili kişi: harry

    Sorgunuzu doğrudan bize gönderin (0 / 3000)