logo
Kalite CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1 fabrika
<
Kalite CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1 fabrika
Kalite CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1 fabrika
Kalite CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1 fabrika
Kalite CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1 fabrika
>

CJX2-N AC Geri Kontaktör, 3 Fazlı Geri Kontaktör 3P 4P 9A ~ 95A AC-3 AC-1

Brand Name: Chint
Model Number: CJX2-N-
Place of Origin: Çin
Sertifikasyon: CE,CCC,CB etc.
Minimum Order Quantity: 1 ADET
Price: USD15~USD138
Supply Ability: 1,000pcs / ay
Delivery Time: 5-8 iş günü veya toplu sipariş müzakere
Payment Terms: T/t, Western Union
Standard Packaging: Standart ihracat karton

Product Details


Ana devre akımı: 9-95A Elektrik tipi: AC, AC / DC
Ana devre voltajı: 600V, 220V, 380V, 110V, 24V Kutup sayısı: 3,4
Aşama: 3,1Phase Frekans: 50 / 60Hz
Ürün adı: Ac Kontaktörü CJX2N-D09,3 kutuplu Ac Kontaktörü Anma: 95A
Standart: IEC60947&#39;ye, EN / IEC60947-4-1
Vurgulamak

AC kontaktör anahtarı

,

merkezi AC kontaktör

Product Description

Chint CJX2-N AC Ters Çevirme Kontaktörü 3P, 4P 9A ~ 95A 1810, 2510, 3210, 6511, AC-3 AC-1 Bobin Gerilimi 24V, 110V, 230V, 380V

karakteristik
• Akım aralığı 09 ~ 95A;
• AC, DC kontrol bobini isteğe bağlıdır (38C'ye DC bobini);
• Farklı tipte starterler mevcuttur: standart motor start kontaktörleri, geri dönüşümlü kontaktörler, yıldız üçgen starterler, ototransformer starterler, vb.
• İsteğe bağlı bağlantı: cıvata bağlantısı (09 ​​~ 620A), halka terminal bağlantısı (09 ​​~ 38A), terminal bağlantısı (40 ~ 65A), müşteri montajı için uygun;
• Ürün Belgelendirme: CCC, CE, CCS;


avantaj
• Kompakt kurulum
> 38A kontaktörleri ve koruma bileşenleri sadece 45mm genişliğindedir
> Aşırı gerilim önleyici kurulum alet gerektirmez ve daha fazla yer kaplamaksızın doğrudan kontaktöre yerleştirilebilir
> Ters çevrilebilir kontaktör sadece 90mm genişliğindedir, mekanik kilitleme fazladan yer kaplamaz, kurulum neredeyse zaman almaz
> Starter bileşenleri hızlı ve kolay montaj için önceden kablolanmış modüller sağlar
• Son derece entegre
> 100A kontaktör entegrasyonu için 1 normalde açık / 1 normalde kapalı yardımcı kontak
> Dahili çift yönlü baskılama diyotlu DC bobin
> Dahili çift yönlü bastırma diyotlu ters çevrilebilir kontaktör grubu
• Güvenli ve güvenilir
> Kontrol ve koruma bileşenlerinin ana devresi ve kontrol devresi açıkça ayırt edilir
> Güvenlik standartlarını karşılayan ve 10 milyon güvenilir eylemi sağlayan aynalı temas tasarımı
> Koruyucu kapak, kontaktörün kazayla temasını önler
• üstün kalite
> DC bobinleri çok çeşitli kontrol voltajlarına sahiptir (0,7 ~ 1,25Uc)
> Güçlü depreme dayanıklı
> düşük ses
> Artan terminal gücü
CJX2 40-65A:
> Kalıcı tork, güvenilir kurulum
> Kompakt ve yerden tasarruf
> Kurulumu kolay, zaman kazandırır
> Kolay bakım ve maliyet tasarrufu

main information
Product Series
NC
product name
devre açıcı
product type
Reversing contactor
Product short name
CJX2-N
Contactor application area
Applied to AC loads with a power factor greater than or equal to 0.95
Squirrel cage motor for switching on and off normal start
Use category
AC-1
AC-3
Equipment introduction
Pre-assembled with reversible power supply busbar
Number of poles
3P
Power pole contact composition
3 NO
Rated working voltage [Ue]
Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie]
25 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit
40 A 60 °C) on <= 440 V AC AC-1 for power supply circuits
Motor power (kW)
5.5 kW on 220...230 V AC 50/60 Hz
11 kW on 380...400 V AC 50/60 Hz
11 kW on 415...440 V AC 50/60 Hz
15 kW on 500 V AC 50/60 Hz
15 kW on 660...690 V AC 50/60 Hz
Motor power HP (UL / CSA)
3 hp on 230/240 V AC 50/60 Hz for 1-phase motors
5 hp on 200/208 V AC 50/60 Hz for 3-phase motors
2 hp on 115 V AC 50/60 Hz for 1-phase motors
7.5 hp on 230/240 V AC 50/60 Hz for 3-phase motors
15 hp on 460/480 V AC 50/60 Hz for 3-phase motors
20 hp on 575/600 V AC 50/60 Hz for 3-phase motors
Control loop characteristics
AC on 50/60 Hz
Control loop voltage
220 V AC 50/60 Hz
Auxiliary contact type
1 NO + 1 NC
Rated impulse withstand voltage [Uimp]
6 kV in accordance with IEC 60947
Overvoltage category
III
Conventional heating current [Ith]
10 A on <60 °C for signal circuit
40 A on <60 °C for power supply circuit
Rated turn-on capability [Irms]
140 A AC suitable signal circuit in accordance with IEC 60947-5-1
250 A DC suitable signal loop in accordance with IEC 60947-5-1
450 A on 440 V applicable power supply circuit in accordance with IEC 60947
Rated breaking capacity
450 A on 440 V applicable power supply circuit in accordance with IEC 60947
Rated short-time withstand current [Icw]
50 A on <40 °C - 10 minutes for power circuit
120 A on <40 °C - 1 minute for power circuit
240 A on <40 °C - 10 s for power supply circuit
380 A on <40 °C - 1 s for power supply circuit
100 A - 1 s for signal circuits
120 A - 500 ms Applicable signal loop
140 A - 100 ms for signal circuits
Fuses used with relays
10 A gG Applicable signal circuit in accordance with IEC 60947-5-1
63 A gG on ...<= 690 V with type 1 for power supply circuit
40 A gG on ...<= 690 V with type 2 for power supply circuit
Average impedance
2 mΩ - Ith 40 A 50 Hz for power supply circuits
Rated insulation voltage [Ui]
690 V complies with IEC 60947-4-1
600 V CSA certification
600 V UL certification
690 V in accordance with IEC 60947-1
Electrical life
1.65 kA2.s 25 A AC-3 Ue condition <= 440 V
1.4 kA2.s 40 A AC-1 Ue condition <= 440 V
Power consumption per pole
1.25 W AC-3
3.2 W AC-1
Safety cover
band
Interlock type
mechanical
Installation method
Rail mounting
Base plate installation
Standards compliant
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
EN 60947-4-1
certified product
CCC
Wiring ability
Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord without
Control circuit: Bolt fastening 2 Cable 1...4 mm2 cord without
Control circuit: Bolt fastening 1 Cable 1...4 mm2 cord
Control circuit: Bolt fastening 2 Cable 1...2.5 mm2 cord
Control circuit: Bolt fastening 1 Cable 1...4 mm2 hard wire without
Control circuit: Bolt fastening 2 Cable 1...4 mm2 hard wire without
Power circuit: Bolt fastening 1 Cable 2.5...10 mm2 cord without
Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 cord without
Power circuit: Bolt tightening 1 Cable 1...10 mm2 cord
Power circuit: bolt fastening 2 cable 1.5...6 mm2 cord
Power circuit: bolt fastening 1 cable 1.5...10 mm2 hard wire without
Power circuit: Bolt fastening 2 Cable 2.5...10 mm2 hard wire without
Tightening torque
Control circuit: 1.7 Nm Screwdriver with bolt Ø 6 flat
Control circuit: 1.7 Nm Screwdriver with No 2 Phillips screw
Power circuit: 2.5 Nm Screwdriver with bolt Ø 6 flat
Power circuit: 2.5 Nm Screwdriver with No 2 Phillips screw
Action time
12...22 ms closed
4...19 ms break
Safety and reliability
B10d = 1369863 Contactors with nominal load compliance in accordance with EN/ISO 13849-1
B10d = 20000000 mechanical load contactors comply with EN/ISO 13849-1
Mechanical life
15 kA2.s
Maximum operating frequency
3600 times / hour on ... <60 °C
Additional information
Surge suppression module
No built-in surge suppression module
Control voltage limit
Release: 0.3...0.6 Uc on 50/60 Hz 60 °C)
Operation: 0.8...1.1 Uc on 50 Hz 60 °C)
Operation: 0.85...1.1 Uc on ... 60 Hz 60 °C)
(~50Hz pull-in) power consumption (VA)
70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA)
7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
Heat dissipation
2...3 W on 50/60 Hz
Auxiliary contact type
Type mechanical connection 1 NO + 1 NC in accordance with IEC 60947-5-1
Type mirrored to the main contact state 1 NC in accordance with IEC 60947-4-1
Signal loop frequency
25...400 Hz
Minimum switching current [Imin]
5 mA suitable signal loop
Minimum switching voltage
17 V for signal circuit
No overlap time
1.5 ms between power loss NC and NO contact
1.5 ms between the NC and NO contacts
Insulation resistance
> 10 MΩ for signal circuits
surroundings
IP protection level
IP20 front panel complies with IEC 60529
Protective measures
TH conforms to IEC 60068-2-30
Pollution level
3
Operating temperature
-5...60 °C
Storage ambient temperature
-60...80 °C
Ambient air temperature
-40...70 °C (allowed under Uc)
Working elevation
3000 m without
Refractory and resistant to abnormal high temperatures
850 °C in accordance with IEC 60695-2-1
Flame retardant
V1 complies with UL 94
Shock and vibration resistance
Seismic performance contacts open: 2 gn (5...300 Hz)
Seismic performance contact closure: 4 gn (5...300 Hz)
Impact resistance contact closure: 15 gn (11ms)
Impact resistance contacts open: 8 gn (11ms)
height
85 mm
width
90 mm
depth
92 mm
product weight
0.787 kg


Product Highlights

Chint CJX2-N AC Ters Çevirme Kontaktörü 3P, 4P 9A ~ 95A 1810, 2510, 3210, 6511, AC-3 AC-1 Bobin Gerilimi 24V, 110V, 230V, 380V karakteristik • Akım aralığı 09 ~ 95A; • AC, DC kontrol bobini isteğe bağlıdır (38C'ye DC bobini); • Farklı tipte starterler mevcuttur: standart motor start kontaktörleri, ...

Related Products
Kalite Yüklemeye hazır Tipi MCB Dağıtım Kutusu RCCB RCBO Ev AC220 ~ 240 V Gelen 63A fabrika

Yüklemeye hazır Tipi MCB Dağıtım Kutusu RCCB RCBO Ev AC220 ~ 240 V Gelen 63A

Ready to Install Type A Distribution Box with MCB, RCCB or RCBO Custom for Home Use AC220~240V Incoming 63A Material: ABS/PC Color: Grey White/Transparent Cover Application: Power Distributing Type: Distribution Box Electrical Boxes Installation Type: Surface Type/ Flush Type Standard: IEC60439-3 ...

Kalite 6kA Elektrik Devre Kesici, 2 Kutuplu Devre Kesici 1 ~ 63A 1 P 3 P 4 P 1 P + N fabrika

6kA Elektrik Devre Kesici, 2 Kutuplu Devre Kesici 1 ~ 63A 1 P 3 P 4 P 1 P + N

Osmart OSMC32N 6kA Schneider Electric Miniature Circuit Breaker 1~63A, 1P,2P,3P,4P,1P+N in compliance with IEC-EN60898 Osmart OSMC32N MCBs Schneider Electric Original Made In China Miniature Circuit Breakers up to 63 A characteristic * Product standard: GB10963.1/IEC 60898 * Product Certification: ...

Kalite Tek RGB Şişme Led Işık Renk Değiştirme, Olaylar Aydınlatma Balon Led Fener Işıkları fabrika

Tek RGB Şişme Led Işık Renk Değiştirme, Olaylar Aydınlatma Balon Led Fener Işıkları

Single RGB LED lighting Source Muse™130C Events Lighting Balloon with 72w/96w Color Changing LED 1. General features Smart Color LED changer balloon light Muse-Color Dual White, Muse-Color RGB+CCTpowered by LED bulb 72w, max 96w Print your company logo or event name on our giant advertising balloon ...

Kalite Dijital Ayar Modüler Zamanlama Röleleri AC DC 12V 24V fabrika

Dijital Ayar Modüler Zamanlama Röleleri AC DC 12V 24V

RT8-K Digital Setting Timer Relay AC DC 12V 24V 220V 230V Multifunction Time Delay on off Relay General Multifunctional time relay with digital settings can be used for industrial equipment, lighting control, heating element control, motor and fan control. It has four delay modes and the delay range ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.