Wuxi Fenigal Science & Technology Co., Ltd.
Endüstriyel ve aydınlatma ürünleri üreticisi ve tedarikçisi
Wuxi Fenigal Science & Technology Co., Ltd.
Endüstriyel ve aydınlatma ürünleri üreticisi ve tedarikçisi
Menşe yeri: | Çin |
Marka adı: | IONPURE |
Sertifika: | CE |
Model numarası: | IP-LX8000Z-5 |
Belge: | fgwater-ionpure-lxz-ds.pdf |
Min sipariş miktarı: | 1 PC |
---|---|
Fiyat: | Anlaşılabilir |
Ambalaj bilgileri: | Standart İhracat Paketleme |
Teslim süresi: | 5- 8 iş günü |
Ödeme koşulları: | T/T, Western Union |
Yetenek temini: | Ayda 60000 adet |
Modülün IP-LXM8000Z-5 Minimum Akış Hızı M3/Saat (GPM): | 2,57 (11,3) | Modülün IP-LXM8000Z-5 Tasarım Akış Hızı M3/HR (GPM): | 5,1-7,67 (22,5-33,8) |
---|---|---|---|
IP-LXM8000Z-5 Nakliye Ağırlığı Kg (LBS): | 205 (451) | IP-LXM8000Z-5 İşletim Ağırlığı Kg (LBS): | 157 (345) |
IP-LXM8000Z-5 Kurtarma: | %90–95 | Avantajlar: | Mega akış kapasitesi |
Silika (SiO2) Giderimi: | Besleme koşullarına bağlı olarak %90–99 | Ph: | 4-11 |
Vurgulamak: | IONPURE CEDI module 7.5-10m3/hr,Mega flow capacity EDI module,IP-LXM8000Z-5 CEDI water treatment module |
Attribute | Value |
---|---|
Minimum Flow Rate m3/hr (gpm) | 2.57 (11.3) |
Design Flow Rate m3/hr (gpm) | 5.1-7.67 (22.5-33.8) |
Shipping Weight kg (lbs) | 205 (451) |
Operating Weight kg (lbs) | 157 (345) |
Recovery | 90–95% |
Silica (SiO2) Removal | 90–99%, depending on feed conditions |
pH Range | 4-11 |
The IONPURE® LX8000Z IP-LXM8000Z-5 represents a breakthrough in industrial-scale continuous electro-deionization (CEDI) technology, delivering unprecedented flow rates without chemical regeneration. Designed for megaprojects requiring massive ultra-pure water (UPW) volumes—such as photovoltaic manufacturing, power generation, and large-scale chemical processing—this membrane stack leverages patented CEDI innovations to replace hazardous mixed-bed ion exchange systems.
CE mark certified, each module is strictly tested before leaving the factory to meet industry standards. Manufactured under ISO 9001 and ISO 14000 quality and environmental management systems.
The module should be installed indoors, away from direct sunlight, with ambient temperature not exceeding 45°C (113°F) to ensure stable and efficient operation.
Parameter | Value |
---|---|
Recovery | 90-95% |
DC Voltage | 0-400V |
DC Amperage | 1.0-6.0A |
Product Resistivity | Minimum Flow >17 MW-cm, Maximum Flow >7 MW-cm |
Silica (SiO2) Removal | 90-99%, depending on feed conditions |
Parameter | Requirement |
---|---|
Conductivity | <40 μS/cm |
Temperature | 5-45°C (41-113°F) |
Inlet Pressure | 1.4-6.9 bar (20-100 psig) |
Total Chlorine | <0.05 ppm |
pH | 4-11 |
E-Cell EDI technology has been successfully applied in power, petroleum, chemical, steel, pharmaceutical, and electronics industries.
For application cases, please visit: www.fgwater.com/Industries/
İlgili kişi: Mr. Harry
Tel: +86-13646187144